PULS ML15.121 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and is classified as NEC Class 2. This unit provides a rated current of 1.3A at 12Vdc and features screw-clamp connections for secure installation. It supports a wide supply voltage range from 85Vac to 264Vac (with specific nominal values listed) and from 88Vdc to 375Vdc, accommodating both single-phase (1AC) or DC networks. The ML15.121 measures 22.5mm in width, 75mm in height, and 91mm in depth, housed in a PC / ABS blend for durability. It delivers an adjustable output voltage between 12Vdc and 15Vdc, with a rated power of 15W. Protection is provided by an NTC (input inrush current limiter), and the unit boasts an efficiency rate of up to 0.83 depending on the input voltage. It has a maximum inrush current consumption of 31A (at 230Vac input), a start-up delay of 780ms, and a rise time of 12ms. Power dissipation is calculated at 3.2W, with an electrical durability of 125,000 hours at +40°C. The output stage features a ripple of 75mVpp and a capacitance of 1650µF.
Quick Quote
PULS CP20.241-S2 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing. It has a net width of 48 mm and operates within an ambient air temperature range of -25 to +70°C. The unit exhibits a current consumption of 11A peak max. inrush at 230Vac input and 7A peak max. inrush at 120Vac input. Its efficiency rates are 0.956 at 230Vac input, 0.942 at 120Vac input, and 0.936 at 100Vac input. The dimensions of the CP20.241-S2 are W48mm x H124mm x D127mm. It includes a 450ms start-up delay for 100-230Vac input, with rise times of 145ms and 160ms under specified conditions. The unit is equipped with protection functions including output overvoltage protection and overload/short-circuit protection, and supports series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.1 W at full output load with 230Vac input and 29.6 W with 120Vac input. The output stage capacitance is 8500 µF. Electrical durability spans from 31,000 to 488,000 hours under various conditions. Ripple is maintained at 50mVpp across a 20Hz to 20MHz range. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features push-in spring connections for ease of installation. The supply voltage ranges from 88Vdc to 180Vdc for DC and 85Vac to 264Vac for AC, with a rated current of 20A at 24Vdc. It is suitable for single-phase (1AC) or DC networks, offering a rated power of 480W. The output voltage is adjustable between 24Vdc and 28Vdc, with a 500mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input.
Quick Quote
PULS QS5.241 is a power supply unit designed for AC/DC conversion with a 50% power reserve, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and features a DC-OK relay contact output for enhanced monitoring. The unit provides a rated current of 5A at 24Vdc and 4.5A at 28Vdc, with spring-clamp connections facilitating secure and reliable connectivity. It supports a wide supply voltage range from 85Vac to 264Vac across various nominal values and from 88Vdc to 360Vdc, ensuring flexibility across different power networks. The QS5.241, part of the Q-series, is housed in an aluminium casing, measuring 40mm in width, 124mm in height, and 117mm in depth. It delivers a rated power of 120W at 24V and 126W at 28V, with a short-term capacity of 180W for up to 4 seconds. The output voltage is adjustable between 24Vdc and 28Vdc, with comprehensive protection functions including output overvoltage protection and overload/short-circuit protection. It allows for series or parallel operation to increase output power and is designed to handle back-feeding loads without malfunctioning. The unit boasts high efficiency rates up to 0.927 depending on the input voltage and has a peak current consumption of 15A. It features a start-up delay of 85-120ms, with a rise time of 18ms to 38ms depending on load capacitance, and a hold time of 34ms to 65ms. Power dissipation is minimized, and the unit demonstrates exceptional electrical durability, with operational lifespans ranging up to 252000 hours under optimal conditions. The output stage capacitance is 3500µF, and ripple is maintained at 50mVpp, ensuring stable power delivery.
Quick Quote
PULS PIM60.241 is a power supply unit that functions as an AC/DC PSU/converter with DIN rail mounting. It operates within an ambient air temperature range of -10 to +60°C, with linear derating up to +70°C. The unit features a DC-OK relay contact output and provides a rated current of 3.8A at 24Vdc within -10 to +60°C and 2.8A at 24Vdc at +70°C. It is equipped with push-in spring connections for connectivity and supports a supply voltage range of 90Vac-264Vac across various nominal voltages from 100Vac to 240Vac at 47-63Hz, with specific input overvoltage and turn-on/shutdown voltage specifications. The PIM-series unit measures W36mm x H90mm x D91mm, has an IP20 degree of protection, and is housed in a polycarbonate (PC) material. Designed for single-phase network operation, it has a net width of 36 mm and offers a rated power of 90W at -10 to +60°C, with a linear derating to 67.2W at +70°C. The output voltage is adjustable between 24Vdc and 28Vdc, featuring protection functions against overvoltage and overload/short-circuit conditions. It showcases an efficiency of 0.938 at 230Vac input and 0.921 at 120Vac input, with specific current consumption rates under various conditions. The unit has a 50ms start-up delay, specified rise times, and hold times at different input voltages, along with power dissipation/losses and electrical durability ratings under various conditions. The ripple is noted at 100mVpp, and the output stage capacitance is 1600 µF.
Quick Quote
PULS CP5.241 is a power supply unit designed for DIN rail mounting with a net width of 32 mm and an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C. The unit features a current consumption of 7A peak max. inrush at both 230Vac and 120Vac inputs. Its efficiency rates are 0.943 at 230Vac input, 0.935 at 120Vac input, and 0.927 at 100Vac input. The dimensions of the CP5.241 are W32mm x H124mm x D102mm. It has a start-up delay of 380-420ms for 100-230Vac input, with rise times of 80ms and 100ms under nominal input with constant full current load at 0mF and 5mF load capacitance, respectively. The unit includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 7.3 W at 230Vac input and 8.2 W at 120Vac input with full output load. The output stage capacitance is 1800 µF. Electrical durability varies with conditions, reaching up to 775000 hours at 25°C and 2.5A output with 1AC 230Vac input. The ripple is 50mVpp across 20Hz to 20MHz at 50Ω. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 35ms at 120/230Vac input.
Quick Quote
PULS CP20.241-R2 is a DIN rail mounting power supply unit housed in an aluminium casing, designed for a wide range of industrial applications. It operates within an ambient air temperature range of -40 to +70°C and offers a net width of 48mm. The unit consumes current differently based on the input voltage: 2.25A at 230Vac, 4.28A at 120Vac, 5.17A at 100Vac input for full output, and 4.64A at 110Vdc input for a 24Vdc / 10A output, with peak inrush currents of 5.5A at 230Vac and 12A at 120Vac. It boasts an efficiency of 0.952 at 230Vac input and 0.938 at 120Vac input. The dimensions are W48mm x H124mm x D127mm. The power supply features a 450ms start-up delay and a rise time of 145ms to 160ms under nominal input conditions. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation losses are 24.2W at 230Vac input and 31.7W at 120Vac input, with an output stage capacitance of 8000µF. Electrical durability ranges from 25,000 to 465,000 hours depending on the operating conditions. The ripple is specified at 100mVpp. This AC/DC power supply unit is part of the CP-series and is designed with built-in decoupling MOSFET for redundancy, hot-swappable connectors, and ATEX approval. It offers a 20% power reserve and features a DC-OK relay contact output. The connection type is hot-swappable connectors. Supply voltage ranges from 88Vdc to 180Vdc for DC and 85Vac to 264Vac for AC, with specific tolerances for overvoltage and shutdown voltages. The rated current is 24A at 48Vdc in temperatures up to +45°C, with derating at higher temperatures. It supports single-phase (1AC) or DC networks and provides a rated power of 576W at temperatures up to +45°C, with linear derating up to +70°C. The output voltage is fixed at 24Vdc, with a 1000mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input.
Quick Quote
PULS ML30.101 is a power supply unit designed for AC/DC conversion with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and adheres to NEC Class 2 design specifications. This unit offers a rated current of 5A at 5Vdc and features spring-clamp connections for secure attachment. It supports a wide supply voltage range from 85Vac to 264Vac across various nominal values (100Vac/110Vac/120Vac/200Vac/208Vac/220Vac/230Vac/240Vac; 47-63Hz) with a turn-ON voltage of 46Vac and a shutdown voltage of 44Vac. Additionally, it can operate with DC supply voltages between 88Vdc and 375Vdc, covering several nominal values (100Vdc/110Vdc/120Vdc/127Vdc/200Vdc/220Vdc/250Vdc). The ML30.101 is housed in a PC/ABS blend, measuring 45mm in width, 75mm in height, and 91mm in depth. It is compatible with single-phase (1AC) or DC networks, has a rated power of 25W, and provides an adjustable output voltage range of 5Vdc to 5.5Vdc with a 250mV turn-ON overshoot. Protection is ensured through an NTC (input inrush current limiter), and the unit exhibits an efficiency of 0.8 at 230Vac input. It has a maximum inrush current consumption of 17A at 120Vac input and 35A peak at 230Vac input, with power dissipation/losses of 6.3W and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω.
Quick Quote
PULS CT10.241 is a DIN rail mounting power supply unit with an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 62 mm. The unit consumes 0.6A with a 3 x 480Vac input and 0.7A with a 3 x 400Vac input for full 24Vdc output, featuring a peak inrush current of 10A for both input conditions. It boasts an efficiency of 0.929 for 3x480Vac input and 0.928 for 3x400Vac input. The dimensions are W62mm x H124mm x D117mm. It includes a 90ms start-up delay and a rise time of 40ms under nominal input with a constant full current load and 0mF load capacitance, extending to 85ms with 10mF load capacitance. The power supply unit is equipped with protection functions including output overvoltage protection and an active input inrush current limiter, supporting overload/short-circuit conditions with a continuous current of max. 23A. It allows for series/parallel operation to increase output power, with a back-feeding load resistance up to 35V. Power dissipation/losses are 18.3 W for 3x480Vac input and 18.6 W for 3x400Vac input, with an output stage capacitance of 6500 µF. Electrical durability ranges from 36,000 to 410,000 hours across various conditions. The ripple is 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit, part of the CT-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and supports a supply voltage of 323Vac-576Vac (wide range; 3-phase input) with a rated current of 12A at 24Vdc (-25...+45°C) and 7.5A at 24Vdc (-25...+70°C). The output voltage is adjustable between 24Vdc and 28Vdc, with a hold time of 54ms at 3x480Vac input and 34ms at 3x400Vac input.
Quick Quote
PULS ML90.200 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and adheres to NEC Class 2 design specifications. This unit offers a rated current of 3.75A at 24Vdc with a derating of 2W from +60°C to +70°C. It features spring-clamp connections for secure and efficient connectivity. The supply voltage accommodates a wide range from 323Vac to 576Vac, supporting various nominal voltages such as 380Vac, 400Vac, 415Vac, 440Vac, 480Vac, 500Vac, and 525Vac, with a frequency range of 47-63Hz and a 2-phase input. The dimensions of the ML90.200 are W72.5mm x H75mm x D103mm, constructed from a PC / ABS blend housing for durability. It is designed for a 2-phase AC network, with a net width of 72.5 mm. The rated power is 90W, and the output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include an NTC for input inrush current limiting. The efficiency rates are 0.89 at 480Vac input and 0.895 at 400Vac input. Current consumption can reach up to 36A max inrush at 2x400Vac input and 45A peak max inrush at 2x480Vac input. Power dissipation/losses are calculated at 10.5 W, with a ripple of 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Quick Quote
PULS ML60.121 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and adheres to NEC Class 2 design specifications. This unit provides a rated current of 4.5A at 12Vdc and features screw-clamp connections for secure installation. It supports a wide supply voltage range from 85Vac to 264Vac (with specific nominal values across 100Vac to 240Vac at 47-63Hz, including a 75Vac turn-ON voltage and a 65Vac shutdown voltage) and 88Vdc to 375Vdc (with nominal values from 100Vdc to 250Vdc), making it versatile for various electrical environments. The ML60.121 measures 45mm in width, 75mm in height, and 91mm in depth, housed in a PC / ABS blend for durability. It is compatible with single-phase (1AC) or DC networks, offering a rated power of 54W and an adjustable output voltage range from 12Vdc to 15Vdc, with a 200mV turn-ON overshoot. Protection is provided by an NTC (input inrush current limiter), and the unit boasts an efficiency of 0.872 at 230Vac input, 0.853 at 120Vac input, and 0.835 at 100Vac input. Current consumption peaks at 16A max inrush (at 120Vac input) and 32A peak max inrush (at 230Vac input), with a 90-120ms start-up delay and a 40-50ms/90-110ms rise time under nominal input conditions. Power dissipation/losses are calculated at 7.9 W, with an electrical durability of 56,000 hours at +40°C. The output stage ripple is 50mVpp (20Hz to 20MHz; 50Ω), and the capacitance at the output stage is 3000µF.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
ML15.121 PULS ML15.121 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and is classified as NEC Class 2. This unit provides a rated current of 1.3A at 12Vdc and features screw-clamp connections for secure installation. It supports a wide supply voltage range from 85Vac to 264Vac (with specific nominal values listed) and from 88Vdc to 375Vdc, accommodating both single-phase (1AC) or DC networks. The ML15.121 measures 22.5mm in width, 75mm in height, and 91mm in depth, housed in a PC / ABS blend for durability. It delivers an adjustable output voltage between 12Vdc and 15Vdc, with a rated power of 15W. Protection is provided by an NTC (input inrush current limiter), and the unit boasts an efficiency rate of up to 0.83 depending on the input voltage. It has a maximum inrush current consumption of 31A (at 230Vac input), a start-up delay of 780ms, and a rise time of 12ms. Power dissipation is calculated at 3.2W, with an electrical durability of 125,000 hours at +40°C. The output stage features a ripple of 75mVpp and a capacitance of 1650µF. | Puls | Quick Quote | |||
CP20.241-S2 PULS CP20.241-S2 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing. It has a net width of 48 mm and operates within an ambient air temperature range of -25 to +70°C. The unit exhibits a current consumption of 11A peak max. inrush at 230Vac input and 7A peak max. inrush at 120Vac input. Its efficiency rates are 0.956 at 230Vac input, 0.942 at 120Vac input, and 0.936 at 100Vac input. The dimensions of the CP20.241-S2 are W48mm x H124mm x D127mm. It includes a 450ms start-up delay for 100-230Vac input, with rise times of 145ms and 160ms under specified conditions. The unit is equipped with protection functions including output overvoltage protection and overload/short-circuit protection, and supports series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.1 W at full output load with 230Vac input and 29.6 W with 120Vac input. The output stage capacitance is 8500 µF. Electrical durability spans from 31,000 to 488,000 hours under various conditions. Ripple is maintained at 50mVpp across a 20Hz to 20MHz range. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features push-in spring connections for ease of installation. The supply voltage ranges from 88Vdc to 180Vdc for DC and 85Vac to 264Vac for AC, with a rated current of 20A at 24Vdc. It is suitable for single-phase (1AC) or DC networks, offering a rated power of 480W. The output voltage is adjustable between 24Vdc and 28Vdc, with a 500mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input. | Puls | Quick Quote | |||
QS5.241 PULS QS5.241 is a power supply unit designed for AC/DC conversion with a 50% power reserve, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and features a DC-OK relay contact output for enhanced monitoring. The unit provides a rated current of 5A at 24Vdc and 4.5A at 28Vdc, with spring-clamp connections facilitating secure and reliable connectivity. It supports a wide supply voltage range from 85Vac to 264Vac across various nominal values and from 88Vdc to 360Vdc, ensuring flexibility across different power networks. The QS5.241, part of the Q-series, is housed in an aluminium casing, measuring 40mm in width, 124mm in height, and 117mm in depth. It delivers a rated power of 120W at 24V and 126W at 28V, with a short-term capacity of 180W for up to 4 seconds. The output voltage is adjustable between 24Vdc and 28Vdc, with comprehensive protection functions including output overvoltage protection and overload/short-circuit protection. It allows for series or parallel operation to increase output power and is designed to handle back-feeding loads without malfunctioning. The unit boasts high efficiency rates up to 0.927 depending on the input voltage and has a peak current consumption of 15A. It features a start-up delay of 85-120ms, with a rise time of 18ms to 38ms depending on load capacitance, and a hold time of 34ms to 65ms. Power dissipation is minimized, and the unit demonstrates exceptional electrical durability, with operational lifespans ranging up to 252000 hours under optimal conditions. The output stage capacitance is 3500µF, and ripple is maintained at 50mVpp, ensuring stable power delivery. | Puls | Quick Quote | |||
PIM60.241 PULS PIM60.241 is a power supply unit that functions as an AC/DC PSU/converter with DIN rail mounting. It operates within an ambient air temperature range of -10 to +60°C, with linear derating up to +70°C. The unit features a DC-OK relay contact output and provides a rated current of 3.8A at 24Vdc within -10 to +60°C and 2.8A at 24Vdc at +70°C. It is equipped with push-in spring connections for connectivity and supports a supply voltage range of 90Vac-264Vac across various nominal voltages from 100Vac to 240Vac at 47-63Hz, with specific input overvoltage and turn-on/shutdown voltage specifications. The PIM-series unit measures W36mm x H90mm x D91mm, has an IP20 degree of protection, and is housed in a polycarbonate (PC) material. Designed for single-phase network operation, it has a net width of 36 mm and offers a rated power of 90W at -10 to +60°C, with a linear derating to 67.2W at +70°C. The output voltage is adjustable between 24Vdc and 28Vdc, featuring protection functions against overvoltage and overload/short-circuit conditions. It showcases an efficiency of 0.938 at 230Vac input and 0.921 at 120Vac input, with specific current consumption rates under various conditions. The unit has a 50ms start-up delay, specified rise times, and hold times at different input voltages, along with power dissipation/losses and electrical durability ratings under various conditions. The ripple is noted at 100mVpp, and the output stage capacitance is 1600 µF. | Puls | Quick Quote | |||
CP5.241 PULS CP5.241 is a power supply unit designed for DIN rail mounting with a net width of 32 mm and an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C. The unit features a current consumption of 7A peak max. inrush at both 230Vac and 120Vac inputs. Its efficiency rates are 0.943 at 230Vac input, 0.935 at 120Vac input, and 0.927 at 100Vac input. The dimensions of the CP5.241 are W32mm x H124mm x D102mm. It has a start-up delay of 380-420ms for 100-230Vac input, with rise times of 80ms and 100ms under nominal input with constant full current load at 0mF and 5mF load capacitance, respectively. The unit includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 7.3 W at 230Vac input and 8.2 W at 120Vac input with full output load. The output stage capacitance is 1800 µF. Electrical durability varies with conditions, reaching up to 775000 hours at 25°C and 2.5A output with 1AC 230Vac input. The ripple is 50mVpp across 20Hz to 20MHz at 50Ω. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 35ms at 120/230Vac input. | Puls | Quick Quote | |||
CP20.241-R2 PULS CP20.241-R2 is a DIN rail mounting power supply unit housed in an aluminium casing, designed for a wide range of industrial applications. It operates within an ambient air temperature range of -40 to +70°C and offers a net width of 48mm. The unit consumes current differently based on the input voltage: 2.25A at 230Vac, 4.28A at 120Vac, 5.17A at 100Vac input for full output, and 4.64A at 110Vdc input for a 24Vdc / 10A output, with peak inrush currents of 5.5A at 230Vac and 12A at 120Vac. It boasts an efficiency of 0.952 at 230Vac input and 0.938 at 120Vac input. The dimensions are W48mm x H124mm x D127mm. The power supply features a 450ms start-up delay and a rise time of 145ms to 160ms under nominal input conditions. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation losses are 24.2W at 230Vac input and 31.7W at 120Vac input, with an output stage capacitance of 8000µF. Electrical durability ranges from 25,000 to 465,000 hours depending on the operating conditions. The ripple is specified at 100mVpp. This AC/DC power supply unit is part of the CP-series and is designed with built-in decoupling MOSFET for redundancy, hot-swappable connectors, and ATEX approval. It offers a 20% power reserve and features a DC-OK relay contact output. The connection type is hot-swappable connectors. Supply voltage ranges from 88Vdc to 180Vdc for DC and 85Vac to 264Vac for AC, with specific tolerances for overvoltage and shutdown voltages. The rated current is 24A at 48Vdc in temperatures up to +45°C, with derating at higher temperatures. It supports single-phase (1AC) or DC networks and provides a rated power of 576W at temperatures up to +45°C, with linear derating up to +70°C. The output voltage is fixed at 24Vdc, with a 1000mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input. | Puls | Quick Quote | |||
ML30.101 PULS ML30.101 is a power supply unit designed for AC/DC conversion with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and adheres to NEC Class 2 design specifications. This unit offers a rated current of 5A at 5Vdc and features spring-clamp connections for secure attachment. It supports a wide supply voltage range from 85Vac to 264Vac across various nominal values (100Vac/110Vac/120Vac/200Vac/208Vac/220Vac/230Vac/240Vac; 47-63Hz) with a turn-ON voltage of 46Vac and a shutdown voltage of 44Vac. Additionally, it can operate with DC supply voltages between 88Vdc and 375Vdc, covering several nominal values (100Vdc/110Vdc/120Vdc/127Vdc/200Vdc/220Vdc/250Vdc). The ML30.101 is housed in a PC/ABS blend, measuring 45mm in width, 75mm in height, and 91mm in depth. It is compatible with single-phase (1AC) or DC networks, has a rated power of 25W, and provides an adjustable output voltage range of 5Vdc to 5.5Vdc with a 250mV turn-ON overshoot. Protection is ensured through an NTC (input inrush current limiter), and the unit exhibits an efficiency of 0.8 at 230Vac input. It has a maximum inrush current consumption of 17A at 120Vac input and 35A peak at 230Vac input, with power dissipation/losses of 6.3W and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. | Puls | Quick Quote | |||
CT10.241 PULS CT10.241 is a DIN rail mounting power supply unit with an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 62 mm. The unit consumes 0.6A with a 3 x 480Vac input and 0.7A with a 3 x 400Vac input for full 24Vdc output, featuring a peak inrush current of 10A for both input conditions. It boasts an efficiency of 0.929 for 3x480Vac input and 0.928 for 3x400Vac input. The dimensions are W62mm x H124mm x D117mm. It includes a 90ms start-up delay and a rise time of 40ms under nominal input with a constant full current load and 0mF load capacitance, extending to 85ms with 10mF load capacitance. The power supply unit is equipped with protection functions including output overvoltage protection and an active input inrush current limiter, supporting overload/short-circuit conditions with a continuous current of max. 23A. It allows for series/parallel operation to increase output power, with a back-feeding load resistance up to 35V. Power dissipation/losses are 18.3 W for 3x480Vac input and 18.6 W for 3x400Vac input, with an output stage capacitance of 6500 µF. Electrical durability ranges from 36,000 to 410,000 hours across various conditions. The ripple is 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit, part of the CT-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and supports a supply voltage of 323Vac-576Vac (wide range; 3-phase input) with a rated current of 12A at 24Vdc (-25...+45°C) and 7.5A at 24Vdc (-25...+70°C). The output voltage is adjustable between 24Vdc and 28Vdc, with a hold time of 54ms at 3x480Vac input and 34ms at 3x400Vac input. | Puls | Quick Quote | |||
ML90.200 PULS ML90.200 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and adheres to NEC Class 2 design specifications. This unit offers a rated current of 3.75A at 24Vdc with a derating of 2W from +60°C to +70°C. It features spring-clamp connections for secure and efficient connectivity. The supply voltage accommodates a wide range from 323Vac to 576Vac, supporting various nominal voltages such as 380Vac, 400Vac, 415Vac, 440Vac, 480Vac, 500Vac, and 525Vac, with a frequency range of 47-63Hz and a 2-phase input. The dimensions of the ML90.200 are W72.5mm x H75mm x D103mm, constructed from a PC / ABS blend housing for durability. It is designed for a 2-phase AC network, with a net width of 72.5 mm. The rated power is 90W, and the output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include an NTC for input inrush current limiting. The efficiency rates are 0.89 at 480Vac input and 0.895 at 400Vac input. Current consumption can reach up to 36A max inrush at 2x400Vac input and 45A peak max inrush at 2x480Vac input. Power dissipation/losses are calculated at 10.5 W, with a ripple of 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | Quick Quote | |||
ML60.121 PULS ML60.121 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and adheres to NEC Class 2 design specifications. This unit provides a rated current of 4.5A at 12Vdc and features screw-clamp connections for secure installation. It supports a wide supply voltage range from 85Vac to 264Vac (with specific nominal values across 100Vac to 240Vac at 47-63Hz, including a 75Vac turn-ON voltage and a 65Vac shutdown voltage) and 88Vdc to 375Vdc (with nominal values from 100Vdc to 250Vdc), making it versatile for various electrical environments. The ML60.121 measures 45mm in width, 75mm in height, and 91mm in depth, housed in a PC / ABS blend for durability. It is compatible with single-phase (1AC) or DC networks, offering a rated power of 54W and an adjustable output voltage range from 12Vdc to 15Vdc, with a 200mV turn-ON overshoot. Protection is provided by an NTC (input inrush current limiter), and the unit boasts an efficiency of 0.872 at 230Vac input, 0.853 at 120Vac input, and 0.835 at 100Vac input. Current consumption peaks at 16A max inrush (at 120Vac input) and 32A peak max inrush (at 230Vac input), with a 90-120ms start-up delay and a 40-50ms/90-110ms rise time under nominal input conditions. Power dissipation/losses are calculated at 7.9 W, with an electrical durability of 56,000 hours at +40°C. The output stage ripple is 50mVpp (20Hz to 20MHz; 50Ω), and the capacitance at the output stage is 3000µF. | Puls | Quick Quote |