Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Pilz PILZ-837370 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range, and the device dimensions are 22.5mm in width. It offers an IP40 degree of protection and operates across a frequency range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 415/460Vac for measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W. The operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs.
Quick Quote
Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Quick Quote
Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Quick Quote
Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3).
Quick Quote
Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s.
Quick Quote
Pilz PILZ-761100 is an insulation monitor designed for DIN rail mounting, featuring insulation and earth fault monitoring with limit values that can be set via display and stored on a chip card. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 98 mm. The connection type is plug-in/detachable spring terminals, supporting a supply voltage range of 20.4-264Vac (24Vac / 120Vac / 240Vac nominal) and 20.4-264Vdc (24Vdc / 110Vdc / 120Vdc / 220Vdc / 250Vdc nominal) within the PMD s20 sub-range. The device measures 45mm in width, offers an IP40 degree of protection, and is housed in a PC material. It is rated for 0-400Vac, with a net width of 45 mm and a depth of 120 mm. Power consumption is 2.5 W. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The monitor includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts), 1 x analog input for 2-phase or 3-phase voltage measurement, and features galvanic isolation protection. Digital inputs comprise 1 x reset input, 1 x test input, and 1 x feedback earth.
Quick Quote
Pilz PILZ-890071 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for adjustable switching underload and overload thresholds. The unit also offers adjustable monitoring reaction time and start-up suppression time for tailored operation. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current is 18A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is made via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it supports both single-phase (1AC) and three-phase (3AC) input types, with a measuring voltage range of 0-120Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, with 1 x analog output for voltage (U) and current (I) monitoring.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-838000 Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load. | Pilz | Quick Quote | |||
PILZ-837370 Pilz PILZ-837370 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range, and the device dimensions are 22.5mm in width. It offers an IP40 degree of protection and operates across a frequency range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 415/460Vac for measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W. The operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs. | Pilz | Quick Quote | |||
PILZ-837360 Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation. | Pilz | Quick Quote | |||
PILZ-837305 Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation. | Pilz | Quick Quote | |||
PILZ-827260 Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). | Pilz | Quick Quote | |||
PILZ-827240 Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s. | Pilz | Quick Quote | |||
PILZ-761100 Pilz PILZ-761100 is an insulation monitor designed for DIN rail mounting, featuring insulation and earth fault monitoring with limit values that can be set via display and stored on a chip card. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 98 mm. The connection type is plug-in/detachable spring terminals, supporting a supply voltage range of 20.4-264Vac (24Vac / 120Vac / 240Vac nominal) and 20.4-264Vdc (24Vdc / 110Vdc / 120Vdc / 220Vdc / 250Vdc nominal) within the PMD s20 sub-range. The device measures 45mm in width, offers an IP40 degree of protection, and is housed in a PC material. It is rated for 0-400Vac, with a net width of 45 mm and a depth of 120 mm. Power consumption is 2.5 W. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The monitor includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts), 1 x analog input for 2-phase or 3-phase voltage measurement, and features galvanic isolation protection. Digital inputs comprise 1 x reset input, 1 x test input, and 1 x feedback earth. | Pilz | Quick Quote | |||
PILZ-890220 Pilz PILZ-890220 | Pilz | Quick Quote | |||
PILZ-890200 Pilz PILZ-890200 | Pilz | Quick Quote | |||
PILZ-890071 Pilz PILZ-890071 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for adjustable switching underload and overload thresholds. The unit also offers adjustable monitoring reaction time and start-up suppression time for tailored operation. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current is 18A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is made via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it supports both single-phase (1AC) and three-phase (3AC) input types, with a measuring voltage range of 0-120Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, with 1 x analog output for voltage (U) and current (I) monitoring. | Pilz | Quick Quote |