PILZ-837280 Pilz Voltage Relays

Pilz PILZ-837280 Pilz PILZ-837280 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections, and it belongs to the S3UM sub-range. With dimensions of W22.5mm x D122 mm and a net width of 22.5 mm, it offers an IP40 degree of protection. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), and it can measure frequencies from 40 to 400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) for measuring voltage at 440/480Vac. Power consumption is rated at 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).
Pilz

Part#:PILZ-837280

Manufacturer:Pilz

Product Lifecycle:Active

Get a quick Quote!

Pilz PILZ-837280 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections, and it belongs to the S3UM sub-range. With dimensions of W22.5mm x D122 mm and a net width of 22.5 mm, it offers an IP40 degree of protection. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), and it can measure frequencies from 40 to 400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) for measuring voltage at 440/480Vac. Power consumption is rated at 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).

About the manufacturer: Pilz is one of the manufacturers that offers Voltage Relays that you can order at Advantage Electric Supply site. We are at the forefront of driving the evolution of industrial automation. Our company ethos is built on dedication and principles, placing a high priority on safety. Over the years, we have been devoted to creating cutting-edge products and solutions tailored to our customers' requirements.

Check out the PILZ-837280 Pilz price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


PILZ-837280 Description

Pilz PILZ-837280 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections, and it belongs to the S3UM sub-range. With dimensions of W22.5mm x D122 mm and a net width of 22.5 mm, it offers an IP40 degree of protection. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), and it can measure frequencies from 40 to 400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) for measuring voltage at 440/480Vac. Power consumption is rated at 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

with money back guarantee


Warranty On All Parts

Manufacturer warranty


Responsive Customer Support

Let us know how we can help!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts