PULS SLV20.200 is a buffer unit designed with a DC-OK relay contact output and features a buffer module with signaling terminal and an EMC filter with natural convection cooling. It has dimensions of W30mm x H42mm x D14mm and operates on a supply voltage range of 24Vdc to 28.8Vdc, with a rated current of 20A at 24Vdc. This unit is suitable for DIN rail mounting and can operate in ambient air temperatures ranging from -10 to +70°C. The SLV20.200 has a net width of 30 mm and consumes a current of 20A. It is equipped with protection functions against overload, short-circuit, and can handle overload/short-circuit current as well as series/parallel operation, allowing it to bridge mains faults without interruption. The output voltage is fixed at 22.5Vdc, with a time delay of 4s for start-up and a 31ms rise time under nominal input with a constant full current load. The ripple is specified at 200mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Quick Quote
PULS XT40.242 is a power supply unit part of the X-series, designed to function as an AC/DC PSU/converter with a semi-regulated 25% power reserve and a DC-OK relay contact output. It operates on a supply voltage of 3x432-528Vac (with nominal values of 440Vac, 480Vac, 500Vac, 525Vac; frequency 47-63Hz), a turn-on voltage of 3 x 390Vac, and a shutdown voltage of 3 x 355Vac. The unit is housed in aluminium, measures W96mm x H124mm x D159mm, and features screw-clamp connections for installation. It is rated for a current of 40A at 24Vdc and is designed for DIN rail mounting in a 3-phase (3AC) network. The ambient air temperature for operation ranges from -25 to +70°C. The XT40.242 has a peak inrush current consumption of 4A (at 3x480Vac input), a rated power of 960W at 24Vdc (1200W for typ. 15s), and includes protection functions such as output overvoltage protection (29.9Vdc max.) and overload/short-circuit current protection. It is not suitable for parallel operation to increase output power but supports 1+1 redundancy for higher system availability. The unit's efficiency is rated at 0.955 (at 3x480Vac input), with a 350ms start-up delay, and output voltage fixed at 24Vdc. The hold time is 2ms (at 3x480Vdc input), and power dissipation/losses are 45.2W (at full output load). Its electrical durability is rated at 51000 hours (at 40°C; 40A output; 3AC 480Vdc input) and 142000 hours (at 25°C; 40A output; 3AC 480Vdc input), with an output stage capacitance of 20000µF and a ripple of 1500mVpp.
Quick Quote
PULS XT40.481 is a power supply unit part of the X-series, designed to function as an AC/DC PSU/converter with a semi-regulated 25% power reserve and a DC-OK relay contact output. It operates on a supply voltage of 3x360-440Vac (380Vac / 400Vac / 415Vac nominal; 47-63Hz), with a turn-ON voltage of 3 x 325Vac and a shutdown voltage of 3 x 295Vac. The unit is housed in aluminium, featuring screw-clamp connections for secure installation and is designed for DIN rail mounting. It supports a 3-phase (3AC) network type and can operate within an ambient air temperature range of -25 to +70°C. The XT40.481 has a net width of 96mm and dimensions of W96mm x H124mm x D159mm. It is rated for a current of 20A at 48Vdc, with a peak inrush current consumption of 4A (at 3x400Vac input). The rated power is 960W at 48Vdc, with a derating to 24W between +60°C and +70°C, and can momentarily support up to 1200W for approximately 15 seconds. Protection features include output overvoltage protection (57.2Vdc max.), active input inrush current limiter, and overload/short-circuit current protection, typically 90A at load impedance. It is not designed for series or parallel operation to increase output power but supports 1+1 redundancy for higher system reliability. The unit is resistant to back-feeding loads up to 55.1V. It boasts an efficiency of 0.96 (at 3x400Vac input), with a 400ms start-up delay, a rise time of 40ms (at nominal input with 0mF load capacitance) to 70ms (with 20mF load capacitance), and a fixed output voltage of 48Vdc with a 1V turn-ON overshoot. The hold time is 3.1ms at 3x400Vdc input, with power dissipation/losses at 40W (full output load). Its electrical durability is rated at 77000 hours (at 40°C; 20A output; 3AC 400Vdc input) to 15 years / 131400 hours (at 25°C; 20A output; 3AC 400Vdc input). The output stage capacitance is 7600µF, with a ripple of 2500mVpp (20Hz...2KHz; 50Ω).
Quick Quote
PULS XT40.721 is a power supply unit part of the X-series, designed to function as an AC/DC PSU/converter with a semi-regulated 25% power reserve and a DC-OK relay contact output. It operates on a supply voltage of 3x360-440Vac (with nominal values of 380Vac, 400Vac, 415Vac; 47-63Hz), featuring a turn-ON voltage of 3 x 325Vac and a shutdown voltage of 3 x 295Vac. The unit is encased in an aluminium housing, measures W96mm x H124mm x D159mm, and uses screw-clamp connections for installation. It is rated for a current of 13.3A at 72Vdc and is designed for DIN rail mounting in a 3-phase (3AC) network. The XT40.721 can operate in ambient air temperatures ranging from -25 to +70°C. It has a peak inrush current consumption of 4A (at 3x400Vac input), a rated power of 24W/+60°C...+70°C (derating) to 960W (at 72Vdc) and 1200W for typical 15s. Protection features include output overvoltage protection (91.1Vdc max.), active input inrush current limiter, and overload/short-circuit current protection. It supports series operation but not parallel operation for increased output power, though 1+1 redundancy for higher system availability and reliability is possible. The unit is resistant to back-feeding loads up to 87.9V. It boasts an efficiency of 0.955 (with 3x400Vac input), a 400ms start-up delay, and a rise time of 40ms to 70ms depending on load capacitance. The output voltage is fixed at 72Vdc with a 1.4V turn-ON overshoot, a hold time of 3.6ms at 3x400Vdc input, power dissipation/losses of 45.2W (at 3x400Vdc input; full output load), an output stage capacitance of 4050 µF, and a ripple of 3000mVpp (20Hz...2KHz; 50Ω).
Quick Quote
PULS YR2.DIODE is a redundancy unit designed for dual-input redundancy module applications, featuring 2 inputs and 1 output based on diode technology with ATEX approval. It operates on a supply voltage range of 9Vdc to 60Vdc, with nominal voltages of 12Vdc, 24Vdc, and 48Vdc. The unit has dimensions of W32mm x H124mm x D102mm and utilizes spring-clamp connections for connectivity. It is rated for a current of 20A at 48Vdc, with a derating to 0.5A between +60°C and +70°C. Designed for DIN rail mounting, it can operate in ambient air temperatures ranging from -40°C to +70°C. The unit has a net width of 32 mm and a peak inrush current consumption of 150A at 9-60Vdc input. It includes protection functions such as short-circuit protection with a 25A threshold at 6V and supports both series/parallel operation for 1+1 redundancy and N+1 redundancy, requiring the use of identical power supplies in parallel. The output voltage range is 12-48Vdc, with power dissipation/losses of 7.8 W for 2x5A input and 17 W for 2x10A input at 9-60Vdc. Its electrical durability is rated at 25 years or 219,000 hours at 40°C for 20A output and 2x5A/10A input, with the same durability at 25°C for 10A output. The ripple is specified as 800mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Quick Quote
PULS FPT500.241-002-101 is a power supply unit from the FPT500 Basic 3AC series designed for field AC/DC power supply or conversion. It features a DC-OK relay contact output within an aluminium housing and utilizes a HanQ4/2 female connector for input, a 5-pin M12 connector for DC-OK, and a HanQ4/0 connector for output. This unit offers protection against output overvoltage, overload, short-circuit, and over-temperature, with specific mechanisms for handling heavy overloads and automatic restarts under certain conditions. It does not support series or parallel operation and is designed to resist back-feeding loads up to 35V / 4J. The rated current is 20.8A at 24Vdc, with a supply voltage range of 323Vac-552Vac across various nominal voltages and frequencies. It is designed for hanging or screw mounting, operates within an ambient air temperature range of -25 to +70°C, and offers IP65 and IP67 protection. The unit operates on a 3-phase network, with specific current consumption and efficiency ratings based on input voltage. It provides a rated power of 600W to 350W depending on the operating temperature, with short-term power availability up to 1000W. The output voltage is adjustable between 24Vdc and 28Vdc, with a specified electrical durability and power dissipation/losses under different conditions.
Quick Quote
Power Supply, IP65/67, 500W, AC 380-480V input, 3 phase, 24-28Vdc output, 20.8A, HAN Q4/2, ASi Cable
Quick Quote
PULS CP5.121 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing and dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit offers a current consumption of 7A peak max inrush at both 230Vac and 120Vac inputs. Its efficiency rates are 0.94 at 230Vac input, 0.932 at 120Vac input, and 0.926 at 100Vac input. The CP5.121 provides a time delay of 350-400ms for start-up and a rise time of 30ms under nominal input with a constant full current load without load capacitance, and 50ms with 10mF load capacitance. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 25V. Power dissipation/losses are 7.7W at full output load with 230Vac input and 8.8W with 120Vac input. The output stage capacitance is 2700 µF. Electrical durability varies with conditions, offering up to 839000 hours at 25°C with 5A output and 1AC 120Vac input. The ripple is 50mVpp across 20Hz to 20MHz at 50Ω. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-150Vdc for DC, with a rated current of 10A at 12Vdc, and provides an adjustable output voltage of 12Vdc-15Vdc. The hold time is 35ms at both 120/230Vac input.
Quick Quote
PULS CP5.241-C1 is a DIN rail mounting power supply unit with an aluminium housing, designed for an ambient air temperature range of -25 to +70°C. It features a net width of 32mm and dimensions of W32mm x H124mm x D102mm. This unit has a current consumption of 7A peak max. inrush at both 230Vac and 120Vac input, with efficiencies of 0.943, 0.935, and 0.927 at 230Vac, 120Vac, and 100Vac inputs respectively. The CP5.241-C1 is equipped with a conformal coated PCB for resistance to harsh environments. It offers a start-up delay of 380-420ms and rise times of 80ms and 100ms under specified conditions. Protection functions include output overvoltage protection and overload/short-circuit protection, with capabilities for series/parallel operation and 1+1 redundancy using a redundancy module. Power dissipation/losses are 7.3W and 8.2W at full output load for 230Vac and 120Vac inputs, respectively. The output stage capacitance is 1800µF, and electrical durability ranges from 96,000 to 775,000 hours under various conditions. The ripple is 50mVpp, and the unit functions as an AC/DC power supply with a 20% power reserve. It belongs to the CP-series and features a design with conformal coating, 20% power reserve, and DC-OK relay contact output. Connection is made via screw-clamp connections. Supply voltage ranges from 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc, and a rated power of 120W. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 35ms.
Quick Quote
PULS CP10.241-60 is a power supply unit designed for DIN rail mounting with an aluminium housing. It operates within an ambient air temperature range of -40 to +70°C and has a net width of 39 mm. The unit features a current consumption of 8A peak max. inrush at both 110Vdc and 96Vdc input. It boasts an efficiency of 0.945 at 110Vdc input and 0.943 at 960Vdc input, with dimensions of W39mm x H124mm x D117mm. The CP10.241-60 has a time delay of 600-700ms for start-up and a rise time of 45ms to 90ms depending on the load capacitance. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation/losses are 11.6 W and 12.1 W for 110Vdc and 96Vdc inputs, respectively, at full output load. The output stage capacitance is 4400 µF. Electrical durability ranges from 112000 to 549000 hours depending on the operating conditions. The ripple is 50mVpp across a 20Hz to 20MHz range. This PSU/DC-DC Converter from the CP-series is designed for railway applications and features a DC-OK relay contact output, spring-clamp connections, and a supply voltage range of 67Vdc-154Vdc. It provides a rated current of 8.3A at 24Vdc, operates on a DC network, and offers a rated power of 200W. The output voltage is adjustable from 24Vdc to 28Vdc with a 200mV turn-ON overshoot, and it has a hold time of 34ms.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
SLV20.200 PULS SLV20.200 is a buffer unit designed with a DC-OK relay contact output and features a buffer module with signaling terminal and an EMC filter with natural convection cooling. It has dimensions of W30mm x H42mm x D14mm and operates on a supply voltage range of 24Vdc to 28.8Vdc, with a rated current of 20A at 24Vdc. This unit is suitable for DIN rail mounting and can operate in ambient air temperatures ranging from -10 to +70°C. The SLV20.200 has a net width of 30 mm and consumes a current of 20A. It is equipped with protection functions against overload, short-circuit, and can handle overload/short-circuit current as well as series/parallel operation, allowing it to bridge mains faults without interruption. The output voltage is fixed at 22.5Vdc, with a time delay of 4s for start-up and a 31ms rise time under nominal input with a constant full current load. The ripple is specified at 200mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | Quick Quote | |||
XT40.242 PULS XT40.242 is a power supply unit part of the X-series, designed to function as an AC/DC PSU/converter with a semi-regulated 25% power reserve and a DC-OK relay contact output. It operates on a supply voltage of 3x432-528Vac (with nominal values of 440Vac, 480Vac, 500Vac, 525Vac; frequency 47-63Hz), a turn-on voltage of 3 x 390Vac, and a shutdown voltage of 3 x 355Vac. The unit is housed in aluminium, measures W96mm x H124mm x D159mm, and features screw-clamp connections for installation. It is rated for a current of 40A at 24Vdc and is designed for DIN rail mounting in a 3-phase (3AC) network. The ambient air temperature for operation ranges from -25 to +70°C. The XT40.242 has a peak inrush current consumption of 4A (at 3x480Vac input), a rated power of 960W at 24Vdc (1200W for typ. 15s), and includes protection functions such as output overvoltage protection (29.9Vdc max.) and overload/short-circuit current protection. It is not suitable for parallel operation to increase output power but supports 1+1 redundancy for higher system availability. The unit's efficiency is rated at 0.955 (at 3x480Vac input), with a 350ms start-up delay, and output voltage fixed at 24Vdc. The hold time is 2ms (at 3x480Vdc input), and power dissipation/losses are 45.2W (at full output load). Its electrical durability is rated at 51000 hours (at 40°C; 40A output; 3AC 480Vdc input) and 142000 hours (at 25°C; 40A output; 3AC 480Vdc input), with an output stage capacitance of 20000µF and a ripple of 1500mVpp. | Puls | Quick Quote | |||
XT40.481 PULS XT40.481 is a power supply unit part of the X-series, designed to function as an AC/DC PSU/converter with a semi-regulated 25% power reserve and a DC-OK relay contact output. It operates on a supply voltage of 3x360-440Vac (380Vac / 400Vac / 415Vac nominal; 47-63Hz), with a turn-ON voltage of 3 x 325Vac and a shutdown voltage of 3 x 295Vac. The unit is housed in aluminium, featuring screw-clamp connections for secure installation and is designed for DIN rail mounting. It supports a 3-phase (3AC) network type and can operate within an ambient air temperature range of -25 to +70°C. The XT40.481 has a net width of 96mm and dimensions of W96mm x H124mm x D159mm. It is rated for a current of 20A at 48Vdc, with a peak inrush current consumption of 4A (at 3x400Vac input). The rated power is 960W at 48Vdc, with a derating to 24W between +60°C and +70°C, and can momentarily support up to 1200W for approximately 15 seconds. Protection features include output overvoltage protection (57.2Vdc max.), active input inrush current limiter, and overload/short-circuit current protection, typically 90A at load impedance. It is not designed for series or parallel operation to increase output power but supports 1+1 redundancy for higher system reliability. The unit is resistant to back-feeding loads up to 55.1V. It boasts an efficiency of 0.96 (at 3x400Vac input), with a 400ms start-up delay, a rise time of 40ms (at nominal input with 0mF load capacitance) to 70ms (with 20mF load capacitance), and a fixed output voltage of 48Vdc with a 1V turn-ON overshoot. The hold time is 3.1ms at 3x400Vdc input, with power dissipation/losses at 40W (full output load). Its electrical durability is rated at 77000 hours (at 40°C; 20A output; 3AC 400Vdc input) to 15 years / 131400 hours (at 25°C; 20A output; 3AC 400Vdc input). The output stage capacitance is 7600µF, with a ripple of 2500mVpp (20Hz...2KHz; 50Ω). | Puls | Quick Quote | |||
XT40.721 PULS XT40.721 is a power supply unit part of the X-series, designed to function as an AC/DC PSU/converter with a semi-regulated 25% power reserve and a DC-OK relay contact output. It operates on a supply voltage of 3x360-440Vac (with nominal values of 380Vac, 400Vac, 415Vac; 47-63Hz), featuring a turn-ON voltage of 3 x 325Vac and a shutdown voltage of 3 x 295Vac. The unit is encased in an aluminium housing, measures W96mm x H124mm x D159mm, and uses screw-clamp connections for installation. It is rated for a current of 13.3A at 72Vdc and is designed for DIN rail mounting in a 3-phase (3AC) network. The XT40.721 can operate in ambient air temperatures ranging from -25 to +70°C. It has a peak inrush current consumption of 4A (at 3x400Vac input), a rated power of 24W/+60°C...+70°C (derating) to 960W (at 72Vdc) and 1200W for typical 15s. Protection features include output overvoltage protection (91.1Vdc max.), active input inrush current limiter, and overload/short-circuit current protection. It supports series operation but not parallel operation for increased output power, though 1+1 redundancy for higher system availability and reliability is possible. The unit is resistant to back-feeding loads up to 87.9V. It boasts an efficiency of 0.955 (with 3x400Vac input), a 400ms start-up delay, and a rise time of 40ms to 70ms depending on load capacitance. The output voltage is fixed at 72Vdc with a 1.4V turn-ON overshoot, a hold time of 3.6ms at 3x400Vdc input, power dissipation/losses of 45.2W (at 3x400Vdc input; full output load), an output stage capacitance of 4050 µF, and a ripple of 3000mVpp (20Hz...2KHz; 50Ω). | Puls | Quick Quote | |||
YR2.DIODE PULS YR2.DIODE is a redundancy unit designed for dual-input redundancy module applications, featuring 2 inputs and 1 output based on diode technology with ATEX approval. It operates on a supply voltage range of 9Vdc to 60Vdc, with nominal voltages of 12Vdc, 24Vdc, and 48Vdc. The unit has dimensions of W32mm x H124mm x D102mm and utilizes spring-clamp connections for connectivity. It is rated for a current of 20A at 48Vdc, with a derating to 0.5A between +60°C and +70°C. Designed for DIN rail mounting, it can operate in ambient air temperatures ranging from -40°C to +70°C. The unit has a net width of 32 mm and a peak inrush current consumption of 150A at 9-60Vdc input. It includes protection functions such as short-circuit protection with a 25A threshold at 6V and supports both series/parallel operation for 1+1 redundancy and N+1 redundancy, requiring the use of identical power supplies in parallel. The output voltage range is 12-48Vdc, with power dissipation/losses of 7.8 W for 2x5A input and 17 W for 2x10A input at 9-60Vdc. Its electrical durability is rated at 25 years or 219,000 hours at 40°C for 20A output and 2x5A/10A input, with the same durability at 25°C for 10A output. The ripple is specified as 800mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | Quick Quote | |||
FPT500.241-002-101 PULS FPT500.241-002-101 is a power supply unit from the FPT500 Basic 3AC series designed for field AC/DC power supply or conversion. It features a DC-OK relay contact output within an aluminium housing and utilizes a HanQ4/2 female connector for input, a 5-pin M12 connector for DC-OK, and a HanQ4/0 connector for output. This unit offers protection against output overvoltage, overload, short-circuit, and over-temperature, with specific mechanisms for handling heavy overloads and automatic restarts under certain conditions. It does not support series or parallel operation and is designed to resist back-feeding loads up to 35V / 4J. The rated current is 20.8A at 24Vdc, with a supply voltage range of 323Vac-552Vac across various nominal voltages and frequencies. It is designed for hanging or screw mounting, operates within an ambient air temperature range of -25 to +70°C, and offers IP65 and IP67 protection. The unit operates on a 3-phase network, with specific current consumption and efficiency ratings based on input voltage. It provides a rated power of 600W to 350W depending on the operating temperature, with short-term power availability up to 1000W. The output voltage is adjustable between 24Vdc and 28Vdc, with a specified electrical durability and power dissipation/losses under different conditions. | Puls | Quick Quote | |||
FPT500.241-006-104 Power Supply, IP65/67, 500W, AC 380-480V input, 3 phase, 24-28Vdc output, 20.8A, HAN Q4/2, ASi Cable | Puls | Quick Quote | |||
CP5.121 PULS CP5.121 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing and dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit offers a current consumption of 7A peak max inrush at both 230Vac and 120Vac inputs. Its efficiency rates are 0.94 at 230Vac input, 0.932 at 120Vac input, and 0.926 at 100Vac input. The CP5.121 provides a time delay of 350-400ms for start-up and a rise time of 30ms under nominal input with a constant full current load without load capacitance, and 50ms with 10mF load capacitance. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 25V. Power dissipation/losses are 7.7W at full output load with 230Vac input and 8.8W with 120Vac input. The output stage capacitance is 2700 µF. Electrical durability varies with conditions, offering up to 839000 hours at 25°C with 5A output and 1AC 120Vac input. The ripple is 50mVpp across 20Hz to 20MHz at 50Ω. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-150Vdc for DC, with a rated current of 10A at 12Vdc, and provides an adjustable output voltage of 12Vdc-15Vdc. The hold time is 35ms at both 120/230Vac input. | Puls | Quick Quote | |||
CP5.241-C1 PULS CP5.241-C1 is a DIN rail mounting power supply unit with an aluminium housing, designed for an ambient air temperature range of -25 to +70°C. It features a net width of 32mm and dimensions of W32mm x H124mm x D102mm. This unit has a current consumption of 7A peak max. inrush at both 230Vac and 120Vac input, with efficiencies of 0.943, 0.935, and 0.927 at 230Vac, 120Vac, and 100Vac inputs respectively. The CP5.241-C1 is equipped with a conformal coated PCB for resistance to harsh environments. It offers a start-up delay of 380-420ms and rise times of 80ms and 100ms under specified conditions. Protection functions include output overvoltage protection and overload/short-circuit protection, with capabilities for series/parallel operation and 1+1 redundancy using a redundancy module. Power dissipation/losses are 7.3W and 8.2W at full output load for 230Vac and 120Vac inputs, respectively. The output stage capacitance is 1800µF, and electrical durability ranges from 96,000 to 775,000 hours under various conditions. The ripple is 50mVpp, and the unit functions as an AC/DC power supply with a 20% power reserve. It belongs to the CP-series and features a design with conformal coating, 20% power reserve, and DC-OK relay contact output. Connection is made via screw-clamp connections. Supply voltage ranges from 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc, and a rated power of 120W. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 35ms. | Puls | Quick Quote | |||
CP10.241-60 PULS CP10.241-60 is a power supply unit designed for DIN rail mounting with an aluminium housing. It operates within an ambient air temperature range of -40 to +70°C and has a net width of 39 mm. The unit features a current consumption of 8A peak max. inrush at both 110Vdc and 96Vdc input. It boasts an efficiency of 0.945 at 110Vdc input and 0.943 at 960Vdc input, with dimensions of W39mm x H124mm x D117mm. The CP10.241-60 has a time delay of 600-700ms for start-up and a rise time of 45ms to 90ms depending on the load capacitance. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation/losses are 11.6 W and 12.1 W for 110Vdc and 96Vdc inputs, respectively, at full output load. The output stage capacitance is 4400 µF. Electrical durability ranges from 112000 to 549000 hours depending on the operating conditions. The ripple is 50mVpp across a 20Hz to 20MHz range. This PSU/DC-DC Converter from the CP-series is designed for railway applications and features a DC-OK relay contact output, spring-clamp connections, and a supply voltage range of 67Vdc-154Vdc. It provides a rated current of 8.3A at 24Vdc, operates on a DC network, and offers a rated power of 200W. The output voltage is adjustable from 24Vdc to 28Vdc with a 200mV turn-ON overshoot, and it has a hold time of 34ms. | Puls | Quick Quote |