A redundancy module is used to decouple two power supplies and ensures the high availability and productivity of your system. A redundant power supply is particularly necessary in applications with stringent demands regarding operational safety.

Puls logo on Advantage Electric Supply
Puls

Found 13 products

YR20.242 on Advantage Electric Supply
Puls

PULS YR20.242 is a redundancy unit from the Y-series designed for dual-input redundancy applications (2 x inputs + 1 x output) with a built-in decoupling MOSFET, suitable for 1+1 or N+1 redundancy configurations and has ATEX approval. It operates on a supply voltage range of 8.4Vdc to 36.4Vdc, with nominal voltages of 12Vdc and 24Vdc. The unit measures 32mm in width, 124mm in height, and 117mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 20A at 28Vdc, with a derating to 1A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can operate in ambient air temperatures from -40°C to +70°C. The YR20.242 provides short-circuit protection with a 26A threshold at 6V and supports both series and parallel operations for 1+1 and N+1 redundancy, ensuring continuous operation by using two or more identical power supplies in parallel. The output voltage is maintained between 12-28Vdc, with nominal values of 12Vdc and 24Vdc. Power dissipation/losses are minimal, ranging from 0.6W with 2x5A input at 8.4-36.4Vdc to 2W with 2x10A input. Its electrical durability is notable, with up to 1563000 hours at 25°C with a 20A output and 2x5A input. The output stage capacitance is 320µF, and the ripple is maintained at 60mVpp across a frequency range of 20Hz to 20MHz at 50Ω.

Quick Quote

PIRD20.241 on Advantage Electric Supply
Puls

Diode redundancy module 24 V, 20 A, 2x 10A; DC-OK relay contact

Quick Quote

YR40.242 on Advantage Electric Supply
Puls

PULS YR40.242 is a redundancy unit belonging to the Y-series, designed with a built-in decoupling MOSFET for 1+1 or N+1 redundancy configurations and holds ATEX approval. It operates with a supply voltage range of 8.4Vdc to 36.4Vdc, supporting nominal voltages of 12Vdc and 24Vdc. The unit measures 36mm in width, 124mm in height, and 127mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 40A at 28Vdc, with a derating to 1A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can function within an ambient air temperature range of -40 to +70°C. The YR40.242 has a peak inrush current consumption of 1000A and includes protection functions against short-circuits, with a threshold of 26A at 6V. It supports both series and parallel operations for 1+1 and N+1 redundancy, ensuring continuous operation by using two or more identical power supplies in parallel. The output voltage is maintained between 12-28Vdc, with power dissipation losses of 1.7W for 2x10A input at 8.4-36.4Vdc and 2.4W for 20A input. Its electrical durability is rated at 672000 hours at 40°C with a 20A output from 2x10A input, and up to 1900000 hours at 25°C with a 40A output from 2x10A input. The output stage capacitance is 320µF, with a ripple of 72mVpp across a frequency range of 20Hz to 20MHz at 50Ω.

Quick Quote

ItemManufacturerPriceStockDelivery
YR20.242 on Advantage Electric Supply

YR20.242

PULS YR20.242 is a redundancy unit from the Y-series designed for dual-input redundancy applications (2 x inputs + 1 x output) with a built-in decoupling MOSFET, suitable for 1+1 or N+1 redundancy configurations and has ATEX approval. It operates on a supply voltage range of 8.4Vdc to 36.4Vdc, with nominal voltages of 12Vdc and 24Vdc. The unit measures 32mm in width, 124mm in height, and 117mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 20A at 28Vdc, with a derating to 1A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can operate in ambient air temperatures from -40°C to +70°C. The YR20.242 provides short-circuit protection with a 26A threshold at 6V and supports both series and parallel operations for 1+1 and N+1 redundancy, ensuring continuous operation by using two or more identical power supplies in parallel. The output voltage is maintained between 12-28Vdc, with nominal values of 12Vdc and 24Vdc. Power dissipation/losses are minimal, ranging from 0.6W with 2x5A input at 8.4-36.4Vdc to 2W with 2x10A input. Its electrical durability is notable, with up to 1563000 hours at 25°C with a 20A output and 2x5A input. The output stage capacitance is 320µF, and the ripple is maintained at 60mVpp across a frequency range of 20Hz to 20MHz at 50Ω.

Puls

Quick Quote

PIRD20.241 on Advantage Electric Supply

PIRD20.241

Diode redundancy module 24 V, 20 A, 2x 10A; DC-OK relay contact

Puls

Quick Quote

YR40.242 on Advantage Electric Supply

YR40.242

PULS YR40.242 is a redundancy unit belonging to the Y-series, designed with a built-in decoupling MOSFET for 1+1 or N+1 redundancy configurations and holds ATEX approval. It operates with a supply voltage range of 8.4Vdc to 36.4Vdc, supporting nominal voltages of 12Vdc and 24Vdc. The unit measures 36mm in width, 124mm in height, and 127mm in depth, featuring screw-clamp connections for secure installation. It is rated for a current of 40A at 28Vdc, with a derating to 1A at temperatures ranging from +60°C to +70°C. Designed for DIN rail mounting, it can function within an ambient air temperature range of -40 to +70°C. The YR40.242 has a peak inrush current consumption of 1000A and includes protection functions against short-circuits, with a threshold of 26A at 6V. It supports both series and parallel operations for 1+1 and N+1 redundancy, ensuring continuous operation by using two or more identical power supplies in parallel. The output voltage is maintained between 12-28Vdc, with power dissipation losses of 1.7W for 2x10A input at 8.4-36.4Vdc and 2.4W for 20A input. Its electrical durability is rated at 672000 hours at 40°C with a 20A output from 2x10A input, and up to 1900000 hours at 25°C with a 40A output from 2x10A input. The output stage capacitance is 320µF, with a ripple of 72mVpp across a frequency range of 20Hz to 20MHz at 50Ω.

Puls

Quick Quote