PILZ-837360 Pilz Voltage Relays

Pilz PILZ-837360 Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Pilz

Part#:PILZ-837360

Manufacturer:Pilz

Product Lifecycle:Active

Get a quick Quote!

Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.

About the manufacturer: Pilz is one of the manufacturers that offers Voltage Relays that you can order at Advantage Electric Supply site. We are at the forefront of driving the evolution of industrial automation. Our company ethos is built on dedication and principles, placing a high priority on safety. Over the years, we have been devoted to creating cutting-edge products and solutions tailored to our customers' requirements.

Check out the PILZ-837360 Pilz price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


PILZ-837360 Description

Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

with money back guarantee


Warranty On All Parts

Manufacturer warranty


Responsive Customer Support

Let us know how we can help!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts