PILZ-837250 Pilz Voltage Relays

Pilz PILZ-837250 Pilz PILZ-837250 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and is designed with a 40 percent hysteresis. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). The connection type is fixed screw terminal connections, and it falls under the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), with a frequency measuring range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 100/110Vac measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).
Pilz

Part#:PILZ-837250

Manufacturer:Pilz

Product Lifecycle:Active

Get a quick Quote!

Pilz PILZ-837250 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and is designed with a 40 percent hysteresis. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). The connection type is fixed screw terminal connections, and it falls under the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), with a frequency measuring range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 100/110Vac measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).

About the manufacturer: Pilz is one of the manufacturers that offers Voltage Relays that you can order at Advantage Electric Supply site. We are at the forefront of driving the evolution of industrial automation. Our company ethos is built on dedication and principles, placing a high priority on safety. Over the years, we have been devoted to creating cutting-edge products and solutions tailored to our customers' requirements.

Check out the PILZ-837250 Pilz price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


PILZ-837250 Description

Pilz PILZ-837250 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and is designed with a 40 percent hysteresis. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). The connection type is fixed screw terminal connections, and it falls under the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The supply voltage requirement is 20.4-26.4Vdc (24Vdc nominal), with a frequency measuring range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 100/110Vac measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

with money back guarantee


Warranty On All Parts

Manufacturer warranty


Responsive Customer Support

Let us know how we can help!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts