ABB 2CDE605200R0021 is a busbar (comb) designed for signal bars for auxiliary contacts, featuring grey insulation. It has a mechanical durability at no load of 21 mm.
Quick Quote
ABB 2CDE601101R2905 is a protection unit designed as an electronic over-current protection device with a rated current of 0.5A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated for use in environments classified as C.
Quick Quote
ABB 2CDE601101R2008 is a protection unit designed as an electronic over-current protection device with an 8A rated current. It operates at a rated voltage of 24 V DC and features an IP20 speed rating. This unit is compatible with a communication protocol width of 80 mm, has a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is designed for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is specified for 0°C minimum temperature and can operate up to a maximum temperature of +50°C. It also has a short circuit current breaking capacity (Icn) rated for C.
Quick Quote
ABB 2CDE601101R2003 is a protection unit designed as an electronic over-current protection device with a rated current of 3A. It operates at a rated voltage (DC) of 24V and features an enclosure with an IP20 rating. The unit has dimensions with a width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The control voltage is specified for AC operation, and the trip unit type is designed for precise operation. The terminals are rated for 0° operation. This protection unit can operate within a temperature range from a minimum of 0°C to a maximum of +50°C. It also has a short circuit current breaking capacity (Icn) suitable for its design specifications.
Quick Quote
ABB 2CDE601101R2010 is a protection unit designed as an electronic over-current protection device with a rated current of 10A. It operates at a rated voltage of 24V DC and features an IP20 speed rating. The unit has dimensions of 80 mm in communication protocol, 12.5 mm for rated impulse voltage (Uimp), and 83 mm for rated insulation voltage (Ui). It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated at C, ensuring its capability to handle specific over-current conditions.
Quick Quote
ABB 2CDE601101R2004 is a protection unit designed as an electronic over-current protection device with a rated current of 4A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. The short circuit current breaking capacity (Icn) is rated for use in environments classified as C.
Quick Quote
ABB 2CDE601101R2012 is a protection unit designed as an electronic over-current protection device with a rated current of 12A. It operates at a rated voltage (DC) of 24V and features an IP20 speed rating. The unit supports a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed for 0°C minimum temperature and can operate up to a maximum temperature of +50°C. It has a short circuit current breaking capacity (Icn) rated for operation in conditions classified as C.
Quick Quote
ABB 2CDE601101R2006 is a protection unit designed as an electronic over-current protection device with a rated current of 6A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit supports a communication protocol with dimensions of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated for C conditions.
Quick Quote
ABB 2CDE601101R2002 is a protection unit designed as an electronic over-current protection device with a rated current of 2A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed for 0°C minimum temperature and can operate up to a maximum temperature of +50°C. It has a short circuit current breaking capacity (Icn) rated for C conditions.
Quick Quote
ABB 2CDE601101R2001 is a protection unit designed as an electronic over-current protection device with a rated current of 1A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated at C.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
2CDE605200R0021 ABB 2CDE605200R0021 is a busbar (comb) designed for signal bars for auxiliary contacts, featuring grey insulation. It has a mechanical durability at no load of 21 mm. | ABB Control | Quick Quote | |||
2CDE601101R2905 ABB 2CDE601101R2905 is a protection unit designed as an electronic over-current protection device with a rated current of 0.5A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated for use in environments classified as C. | ABB Control | Quick Quote | |||
2CDE601101R2008 ABB 2CDE601101R2008 is a protection unit designed as an electronic over-current protection device with an 8A rated current. It operates at a rated voltage of 24 V DC and features an IP20 speed rating. This unit is compatible with a communication protocol width of 80 mm, has a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is designed for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is specified for 0°C minimum temperature and can operate up to a maximum temperature of +50°C. It also has a short circuit current breaking capacity (Icn) rated for C. | ABB Control | Quick Quote | |||
2CDE601101R2003 ABB 2CDE601101R2003 is a protection unit designed as an electronic over-current protection device with a rated current of 3A. It operates at a rated voltage (DC) of 24V and features an enclosure with an IP20 rating. The unit has dimensions with a width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The control voltage is specified for AC operation, and the trip unit type is designed for precise operation. The terminals are rated for 0° operation. This protection unit can operate within a temperature range from a minimum of 0°C to a maximum of +50°C. It also has a short circuit current breaking capacity (Icn) suitable for its design specifications. | ABB Control | Quick Quote | |||
2CDE601101R2010 ABB 2CDE601101R2010 is a protection unit designed as an electronic over-current protection device with a rated current of 10A. It operates at a rated voltage of 24V DC and features an IP20 speed rating. The unit has dimensions of 80 mm in communication protocol, 12.5 mm for rated impulse voltage (Uimp), and 83 mm for rated insulation voltage (Ui). It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated at C, ensuring its capability to handle specific over-current conditions. | ABB Control | Quick Quote | |||
2CDE601101R2004 ABB 2CDE601101R2004 is a protection unit designed as an electronic over-current protection device with a rated current of 4A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. The short circuit current breaking capacity (Icn) is rated for use in environments classified as C. | ABB Control | Quick Quote | |||
2CDE601101R2012 ABB 2CDE601101R2012 is a protection unit designed as an electronic over-current protection device with a rated current of 12A. It operates at a rated voltage (DC) of 24V and features an IP20 speed rating. The unit supports a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed for 0°C minimum temperature and can operate up to a maximum temperature of +50°C. It has a short circuit current breaking capacity (Icn) rated for operation in conditions classified as C. | ABB Control | Quick Quote | |||
2CDE601101R2006 ABB 2CDE601101R2006 is a protection unit designed as an electronic over-current protection device with a rated current of 6A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit supports a communication protocol with dimensions of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated for C conditions. | ABB Control | Quick Quote | |||
2CDE601101R2002 ABB 2CDE601101R2002 is a protection unit designed as an electronic over-current protection device with a rated current of 2A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed for 0°C minimum temperature and can operate up to a maximum temperature of +50°C. It has a short circuit current breaking capacity (Icn) rated for C conditions. | ABB Control | Quick Quote | |||
2CDE601101R2001 ABB 2CDE601101R2001 is a protection unit designed as an electronic over-current protection device with a rated current of 1A. It operates at a rated voltage (DC) of 24 V and features an IP20 speed rating. The unit has a communication protocol width of 80 mm, a rated impulse voltage (Uimp) of 12.5 mm, and a rated insulation voltage (Ui) of 83 mm. It is suitable for DIN rail mounting and utilizes screw-clamp terminals for connection. The trip unit type is designed to operate within a temperature range of 0°C to +50°C. Additionally, it has a short circuit current breaking capacity (Icn) rated at C. | ABB Control | Quick Quote |