Solenoid interlocks; Hygienic design; Protection class IP 69; Suitable for mounting to profile systems; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directions of actuation; Compact design; 3 LEDs to s

About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switch Interlocks that you can order at Advantage Electric Supply site. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Check out the AZM300Z-I1-ST-1P2P-A-T Schmersal price in the box on the right side or send a quick quote.

Product Details

  • Test pulse interval, typical
    1000 ms
  • Current, Utilisation category DC13
    0.05 A
  • Voltage, Utilisation category DC13
    24 VDC
  • Current, Utilisation category DC12
    0.05 A
  • Voltage drop Ud, maximum
    4 V
  • Voltage, Utilisation category DC12
    24 VDC
  • Current leakage Ir
    0.5 mA
  • Versions
    short-circuit proof, p-type
  • Test pulse interval, minimum
    100 ms
  • Classification ZVEI CB24I, Source
    C2
  • Classification ZVEI CB24I, Sink
    C1, C2
  • Test pulse duration, maximum
    0.5 ms
  • Current consumption at 24V
    5 mA
  • Duty cycle solenoid
    100 %
  • Switching thresholds
    −3 V … 5 V (Low), 15 V … 30 V (High)
  • Switching frequency, maximum
    0.5 Hz
  • External wiring and device fuse rating
    2 A gG
  • Current consumption with solenoid ON, peak
    350 mA / 200 ms
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Current consumption with solenoid ON, average
    200 mA
  • No-load supply current I0
    100 mA
  • Notes (Power supply, general)
    stabilised PELV power supply
  • Operating voltage, minimum
    20.4 VDC
  • Operating voltage, maximum
    26.4 VDC
  • Overvoltage category
    III
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Degree of pollution to IEC/EN 60664-1
    3
  • Zulässige Aufstellhöhe über NN, maximum
    2,000 m
  • Protection rating
    III
  • Rated insulation voltage Ui
    32 VDC
  • Note (Relative humidity)
    non-condensing, non-icing
  • Restistance to shock
    30 g / 11 ms
  • Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm
  • Relative humidity, maximum
    93 %
  • Storage and transport temperature, maximum
    +90 °C
  • Storage and transport temperature, minimum
    -10 °C
  • Degree of protection
    IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
  • Ambient temperature, maximum
    +60 °C
  • Length of sensor
    146 mm
  • Height of sensor
    55 mm
  • Ambient temperature, minimum
    +0 °C
  • Width of sensor
    87.5 mm
  • Note (series connection of the sensors)
    Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
  • Note (length of the sensor chain)
    Cable length and cross-section change the voltage drop dependiing on the output current
  • Length of sensor chain, maximum
    200 m
  • Terminal Connector
    Connector M12, 8-pole, A-coded
  • Ensured switch distance ON Sao
    1 mm
  • Ensured switch distance OFF Sar
    20 mm
  • Switch distance
    2 mm
  • Tightening torque of the fixing screws, minimum
    6 Nm
  • Clamping force, maximum Fmax
    1,500 N
  • Type of the fixing screws
    2x M6
  • Latching force, adjustable, position 1
    25 N
  • Tightening torque for the fixing screws, maximum
    7 Nm
  • Latching force, adjustable, position 2
    50 N
  • Angular offset between interlocking device and actuator, maximum
    2 °
  • Clamping force in accordance with ISO14119 Fzh
    1,150 N
  • Note (Mechanical lifetime)
    When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
  • Number of fail-safe digital outputs
    2
  • Short-circuit recognition
    Yes
  • Mechanical life, minimum
    1,000,000 Operations
  • Safety functions
    Yes
  • Series-wiring
    Yes
  • Integral System Diagnostics, status
    Yes
  • Enclosure material
    Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
  • general information
    Individual coding
  • Short circuit detection
    Yes
  • Active principle
    RFID
  • Guard locking monitored
    Yes
  • Emergency exit
    Yes
  • Standards
    EN ISO 13849-1, EN ISO 14119, IEC 60947-5-3
  • Response time safety outputs in case of switch-off by safety inputs, maximum
    1.5 ms
  • Latching
    Yes
  • Power to lock
    Yes
  • Response time safety outputs in case of switch-off by actuator, maximum
    100 ms
  • Time to readiness, maximum
    5,000 ms
  • Frequency band RFID
    125 kHz
  • Coding level according to ISO 14119
    High
  • Gross weight
    639.5 g
  • Duration of risk, maximum
    200 ms
  • Transmit power, maximum
    -6 dB/m

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents AZM300Z-I1-ST-1P2P-A-T Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

with money back guarantee


Warranty On All Parts

Manufacturer warranty


Responsive Customer Support

Let us know how we can help!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts