AZM300B-ST-SD2P-A-T Schmersal Safety Switch Interlocks

AZM300B-ST-SD2P-A-T on Advantage Electric Supply
Schmersal

Part#:AZM300B-ST-SD2P-A-T

Manufacturer:Schmersal

Alt. Part#:103015610

Product Lifecycle:Active

Get a quick Quote!

Solenoid interlocks; Hygienic design; Protection class IP 69; Suitable for mounting to profile systems; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directions of actuation; Compact design; 3 LEDs to s

About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switch Interlocks that you can order at Advantage Electric Supply site. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Check out the AZM300B-ST-SD2P-A-T Schmersal price in the box on the right side or send a quick quote.

Product Details

  • Wiring capacity
    50 nF
  • Current, Utilisation category DC12
    0.05 A
  • Classification ZVEI CB24I, Source
    C2
  • Current leakage Ir
    0.5 mA
  • Test pulse interval, minimum
    100 ms
  • Operation current
    150 mA
  • Current, Utilisation category DC13
    0.05 A
  • Voltage, Utilisation category DC13
    24 VDC
  • Test pulse interval, typical
    1000 ms
  • Voltage drop Ud, maximum
    4 V
  • Voltage, Utilisation category DC12
    24 VDC
  • Versions
    short-circuit proof, p-type
  • Current consumption at 24V
    5 mA
  • Classification ZVEI CB24I, Sink
    C1, C2
  • Test pulse duration, maximum
    0.5 ms
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Duty cycle solenoid
    100 %
  • Switching thresholds
    −3 V … 5 V (Low), 15 V … 30 V (High)
  • Switching frequency, maximum
    0.5 Hz
  • External wiring and device fuse rating
    2 A gG
  • Current consumption with solenoid ON, peak
    350 mA / 200 ms
  • Current consumption with solenoid ON, average
    200 mA
  • Notes (Power supply, general)
    stabilised PELV power supply
  • No-load supply current I0
    100 mA
  • Operating voltage, maximum
    26.4 VDC
  • Operating voltage, minimum
    20.4 VDC
  • Degree of pollution to IEC/EN 60664-1
    3
  • Overvoltage category
    III
  • Rated insulation voltage Ui
    32 VDC
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Zulässige Aufstellhöhe über NN, maximum
    2,000 m
  • Protection rating
    III
  • Restistance to shock
    30 g / 11 ms
  • Note (Relative humidity)
    non-condensing, non-icing
  • Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm
  • Relative humidity, maximum
    93 %
  • Storage and transport temperature, minimum
    -10 °C
  • Storage and transport temperature, maximum
    +90 °C
  • Height of sensor
    55 mm
  • Ambient temperature, minimum
    +0 °C
  • Ambient temperature, maximum
    +60 °C
  • Degree of protection
    IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
  • Width of sensor
    87.5 mm
  • Length of sensor
    146 mm
  • Note (length of the sensor chain)
    Cable length and cross-section change the voltage drop dependiing on the output current
  • Terminal Connector
    Connector M12, 8-pole, A-coded
  • Note (series connection of the sensors)
    Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
  • Length of sensor chain, maximum
    200 m
  • Ensured switch distance ON Sao
    1 mm
  • Latching force, adjustable, position 1
    25 N
  • Ensured switch distance OFF Sar
    20 mm
  • Switch distance
    2 mm
  • Clamping force in accordance with ISO14119 Fzh
    1,150 N
  • Tightening torque for the fixing screws, maximum
    7 Nm
  • Type of the fixing screws
    2x M6
  • Clamping force, maximum Fmax
    1,500 N
  • Latching force, adjustable, position 2
    50 N
  • Tightening torque of the fixing screws, minimum
    6 Nm
  • Angular offset between interlocking device and actuator, maximum
    2 °
  • Integral System Diagnostics, status
    Yes
  • Mechanical life, minimum
    1,000,000 Operations
  • Safety functions
    Yes
  • Note (Mechanical lifetime)
    When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
  • Number of fail-safe digital outputs
    2
  • Series-wiring
    Yes
  • Short-circuit recognition
    Yes
  • Emergency exit
    Yes
  • Short circuit detection
    Yes
  • Actuator monitored
    Yes
  • Latching
    Yes
  • Serial diagnostics
    Yes
  • Power to lock
    Yes
  • Response time safety outputs in case of switch-off by safety inputs, maximum
    1.5 ms
  • Response time safety outputs in case of switch-off by actuator, maximum
    100 ms
  • Time to readiness, maximum
    5,000 ms
  • Duration of risk, maximum
    200 ms
  • general information
    Universal coding
  • Enclosure material
    Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
  • Standards
    EN ISO 13849-1, EN ISO 14119, IEC 60947-5-3
  • Coding level according to ISO 14119
    Low
  • Gross weight
    645 g
  • Active principle
    RFID
  • Transmit power, maximum
    -6 dB/m
  • Frequency band RFID
    125 kHz

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents AZM300B-ST-SD2P-A-T Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

with money back guarantee


Warranty On All Parts

Manufacturer warranty


Responsive Customer Support

Let us know how we can help!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts