Further products/software; Individual coding with RFID technology; Coding level "High" according to ISO 14119; Connector M12, 8-pole; Power to lock; Actuator monitored; Diagnostic output
About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switches that you can order at Advantage Electric Supply site. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Check out the AZM300B-I1-ST-1P2P-A TEST BA Schmersal price in the box on the right side or send a quick quote.
Product Details
- Current, Utilisation category DC13 0.05 A
- Classification ZVEI CB24I, Sink C1, C2
- Test pulse duration, maximum 0.5 ms
- Voltage, Utilisation category DC13 24 VDC
- Voltage, Utilisation category DC12 24 VDC
- Voltage drop Ud, maximum 4 V
- Versions short-circuit proof, p-type
- Classification ZVEI CB24I, Source C2
- Test pulse interval, minimum 100 ms
- Duty cycle solenoid 100 %
- Current consumption at 24V 5 mA
- Switching frequency, maximum 0.5 Hz
- No-load supply current I0 100 mA
- Operating voltage, minimum 20.4 VDC
- Operating voltage, maximum 26.4 VDC
- Current consumption with solenoid ON, peak 350 mA / 200 ms
- Degree of pollution to IEC/EN 60664-1 3
- Resistance to vibrations to EN 60068-2-6 10 … 150 Hz, amplitude 0.35 mm
- Relative humidity, maximum 93 %
- Restistance to shock 30 g / 11 ms
- Note (series connection of the sensors) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Operating current 50 mA
- Test pulse interval, typical 1000 ms
- Current leakage Ir 0.5 mA
- Current, Utilisation category DC12 0.05 A
- Switching thresholds −3 V … 5 V (Low), 15 V … 30 V (High)
- External wiring and device fuse rating 2 A gG
- Required rated short-circuit current to EN 60947-5-1 100 A
- Current consumption with solenoid ON, average 200 mA
- Notes (Power supply, general) stabilised PELV power supply
- Rated impulse withstand voltage Uimp 0.8 kV
- Overvoltage category III
- Rated insulation voltage Ui 32 VDC
- Zulässige Aufstellhöhe über NN, maximum 2,000 m
- Protection rating III
- Ambient temperature, minimum +0 °C
- Note (Relative humidity) non-condensing, non-icing
- Storage and transport temperature, maximum +90 °C
- Ambient temperature, maximum +60 °C
- Storage and transport temperature, minimum -10 °C
- Degree of protection IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
- Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
- Length of sensor chain, maximum 200 m
- Terminal Connector Connector M12, 8-pole, A-coded
- Ensured switch distance OFF Sar 20 mm
- Ensured switch distance ON Sao 1 mm
- Switch distance 2 mm
- Tightening torque for the fixing screws, maximum 7 Nm
- Type of the fixing screws 2x M6
- Tightening torque of the fixing screws, minimum 6 Nm
- Clamping force, maximum Fmax 1,500 N
- Latching force, adjustable, position 1 25 N
- Latching force, adjustable, position 2 50 N
- Clamping force in accordance with ISO14119 Fzh 1,150 N
- Angular offset between interlocking device and actuator, maximum 2 °
- Note (Mechanical lifetime) When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
- Integral System Diagnostics, status Yes
- Mechanical life, minimum 1,000,000 Operations
- Number of safety contacts 2
- Safety functions Yes
- Series-wiring Yes
- Short circuit detection Yes
- Manual release Yes
- Short-circuit recognition Yes
- Latching Yes
- Actuator monitored Yes
- Response time safety outputs in case of switch-off by safety inputs, maximum 1.5 ms
- Power to lock Yes
- Response time safety outputs in case of switch-off by actuator, maximum 100 ms
- Duration of risk, maximum 200 ms
- Gross weight 550 g
- Enclosure material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Frequency band RFID 125 kHz
- Active principle RFID
- general information Individual coding
- Standards EN ISO 13849-1, EN ISO 14119, IEC 60947-5-3
- Time to readiness, maximum 5,000 ms
- Transmit power, maximum -6 dB/m
- Coding level according to ISO 14119 High
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents AZM300B-I1-ST-1P2P-A TEST BA Specs
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
We deliver nationwide and international
Secure Payment Processing
with money back guarantee
Warranty On All Parts
Manufacturer warranty
Responsive Customer Support
Let us know how we can help!
Need more details?
Feel free to chat with us
What can I help you find today?